CMDDA1 - Carbon Monoxide / Carbon Dioxide Atmosphere & Appliance Testing
Course
In Mansfield
Description
-
Type
Course
-
Location
Mansfield
The ACS assessment covering the investigation of a report of smells or fumes is now available. It is NOT a mandatory requirement but will aid a registered gas engineer when responding…
Facilities
Location
Start date
Start date
Reviews
Subjects
- IT
- Testing
Course programme
The ACS assessment covering the investigation of a report of smells or fumes is now available.
It is NOT a mandatory requirement but will aid a registered gas engineer when responding to the following:
CO alarm activation
Report of fumes
Follow up to an emergency service provider visit classifying the installation as a 'concen for safety'
Any other report of fumes
This will also aid the Local Authorities and nominated subcontractors responding to calls from their tenants
CCN1/CCLP1 + CPA1) or CCN1/CCLP1 as from 1st April 2012 or valid equivalent NVQ or QCF qualification + appropriate domestic appliance(s)
Start dates and fees£350.00 fully inclusive of resources, certification with BPEC and hospitality whilst on assessment.
1 day training, 1 day assessment
Location- Construction Centre
Through practical and theoretical assessments.
Practical assessment is carried out on a 1:1 ratio basis.
Assessment is carried out using a variety of assessment methods including multiple choice, short written response and scenario questions and observed practical assessment.
The one day training course will take you to assessment, where after successful completion you will gain certification from BPEC.
What will I study?CMDDA1 is designed to address the investigation of reported fumes, smells or leakage of combustion products in domestic premises through the use of an ECGA (Electronic combustion gas analyser), where conventional safety checks have failed to identify any clear cause(s) e.g. CO alarm activation following a number of past visits to the same property.
You will study:
- Recording and actions when receiving a call for assistance
- The equipment required, recording and actions to take during the investigation
- Procedures for carrying out checks for CO as part of the investigation
- Procedures for carrying out checks as a result of the activation of an electrical CO alarm
- Gas appliance investigation and report
- Combustion Performance Action levels
You could consider the non-domestic courses and widen your portfolio. Examples include:
COCN1 - Core Commercial Gas Safety or CoDNC01 Changeover from Domestic to Commercial
ICPN1 - Commercial Pipework
TPCP1/1A Test and Purge
ICAE1 - Commercial Appliance Installations
CORT1 - Overhead Radiant/Plaque Heaters
CDGA1 - Direct Fired Appliances
CIGA1 - Indirect Fires Appliances
By contacting:
Pam Berry
01623 627191 ext 8509
email: pam.berry@wnc.ac.uk
CMDDA1 - Carbon Monoxide / Carbon Dioxide Atmosphere & Appliance Testing